4/5-Step Block | |
Specifications: ASTM E797 Calibration Function: Straight Beam: thickness and linearity calibration, thickness gauging. |
|
Calibration block No.1(V1) | |
Specifications: ISO2400-2012 Calibration Function: Calibration of shear and compression wave probes. Checking beam angle, emergent point and resolution.Calibration of time base and gain settings. *We can provide V1 calibration block based on ISO2400-2012, BS2704, ASTM E164, ISO2400-1972E, AWS D1.1/D1.1M and AS 2083. |
|
Calibration Block No.2 (V2) | |
Specifications: ISO7963:2010 Calibration Function: Small calibration block for on-site checking of miniature shear wave probe index, time base, beam angle and gain, engraved reference mark scales from 35 to 75 degrees. *We can provide V2 calibration block based on BS2704 and ISO 7963. |
|
Calibration Block No.3 (V3) | |
Calibration Functions:
For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. This block is intended to function as a more compact and light-weight alternative to V1 or IIW-Type Test Blocks. Includes 25mm, 50mm, and 100mm radii, (2)3.0mm diameter through holes, engraved reference mark scales, and a 0.4mm wide * 2.5mm deep slot. |
|
Phased Array Test Block Type A | |
Specifications: ASTME2491-2013 Calibration Functions: The Phased Array “Type A” Calibration Block is used during the initial setup and calibration of a phased array ultrasonic unit. It can be used to perform tasks such as beam angle verification, calibration for wedge delay, sensitivity calibration, performing DAC/TCG for thickness up to 50 mm, and crack sizing. |
|
Phased Array Test Block Type B | |
Specifications: ASTM E2491-2013 Calibration Function: The Phased Array “Type B” Calibration Block is used as baseline block to determine long-term instrument performance changes, generate DAC curves, and evaluate linear/ angular resolution, focusing ability and beam steering capability. |
|
PAUT IIW Test Block | |
Specifications: ISO 19675 Calibration Function: Probe index, beam angle, beam squint angle, linearity of time base, calibration of time base, linearity of attenuator, linearity of screen height, pulse duration, measurement of dominant frequency, signal-to-noise ratio (SNR,) wedge delay, assess for grating lobes, active element assessment, sensitivity equalization for E-scans, sensitivity equalization for S-Scans, plotting check, element assignment, anisotropy assessment. |
|
Miniature Angle Beam (ROMPAS) Calibration Block | |
Specifications: ASTM E164-2013 Calibration Function: Straight Beam: distance angle beam, index point, sound path angle (30°-70°). |
|
DSC Distance/ Sensitivity Calibration Block | |
Specifications: ASTM E164-2013 Calibration Function: Straight Beam: distance, amplitude. Angle Beam: index point, sound path angle (45°-70°),distance, sensitivity. |
|
GSSeries Calibration Block(Set of 7) | |
Specifications: NB/T47013.3-2015 Calibration Function: GS Series Calibration Block is used for ultrasonic testing of circumferentially butt joints (type II welded joints) for pipes (applicable OD range 20-500mm). |
|
DC Distance Calibration Block | |
Specifications: ASTM E164-2013 Calibration Function: Straight Beam: distance, amplitude. Angle Beam: index point, distance. *We can provide DC calibration block based on ASTM E164, AWSD1.1/D1.1M. |
|
SC Sensitivity Calibration Block | |
Specifications: ASTM E164-2013 Calibration Function: Angle Beam: sound path angle (45°, 60°, 75°), sensitivity. *We can provide SC calibration block based on ASTM E164, AWSD1.1/D1.1M. |
|
DS Distance/ Sensitivity Calibration Block | |
Specifications: AWS D1.1/D1.1M-2015 Calibration Function: Straight Beam: distance, horizontal linearity, sensitivity. |
|
RC (AWS) Resolution Calibration Block | |
Specifications: AWS D1.1/D1.1M-2015 Calibration Functions: Angle Beam: resolution (45°, 60°, 70°). |
|
IOW Beam Profile Block | |
Specifications: API RP 2X-2004 Calibration Functions: Angle Beam: beam profile (45°, 60°, 70°), probe angle. *We can provide IOW calibration block based on API RP 2X, BS 2704, AS 2083. |
|
ASME Basic Calibration Blocks | |
Specifications: ASME BPVC-V (2015) Calibration Functions: Used for establishment of primary reference responses for UT examination of welds. |
|
ASME Basic Calibration Blocks for Pipe | |
Specifications: ASME BPVC-V (2015) Calibration Functions: The basic calibration block fabricated for customer supplied section of pipe of the same diameter, schedule, heat treatment and material type as the material being examined. |
|
ASTM Area/ Amplitude (Set of 8) | |
Specifications: ASTM E127-2015 or ASTM E428-2008 Calibration Functions: Determining relationship comparisons of flaw size and echo amplitude. |
|
ASTM Distance/ Area Amplitude (Set of 10) | |
Specifications: ASTM E127-2015 or ASTM E428-2008 Calibration Functions: Determining relationship comparisons of flaw size and echo amplitude. |
|
ASTM Distance Amplitude (Set of 19) | |
Specifications: ASTM E127-2015 or ASTME428-2008 Calibration Functions: Comparisons of distance amplitude relationships. |